Most often it is still hot: the heat sentry holds a Wolf hood on until the exhaust cools. A downdraft may be finishing its delay-off run. If the hood keeps going with everything cold and the knob or button at off, switch it off at the breaker and call Wolf Repair Woodinville, (425) 585-2373.

A hooked lever, a formed bracket, a coil spring, a bushing and a clip beside a flat screwdriver, two nut drivers, pliers and a wire brush

Two-Minute Check

Run it in order. Nothing here needs a panel off, a ladder or a wire touched.

  1. Turn the burners off and give the hood several minutes — a blower still clearing hot exhaust drops back to your setting by itself.
  2. On a pro hood, turn the right-hand blower knob fully counterclockwise until it stops; a knob that spins on without a stop may be broken.
  3. On a downdraft, look for the DELAY light — that timed run can last up to ten minutes and ends with the chimney still raised.
  4. To stop a downdraft yourself, press UP/DOWN, or press LOW and then LOW again; Wolf notes that HIGH and MEDIUM cannot switch it off.
  5. Still running with the cooktop cold? Switch it off at its breaker and leave it off rather than letting it run on.
  6. Stop here — call Wolf Repair Woodinville, (425) 585-2373. Call (425) 585-2373

Two features that look like a fault

The heat sentry on Wolf pro hoods, and several Wolf cooktop hoods, keeps the blower going until the exhaust drops below about 186°F — sometimes a while after a long sear.

Why it starts at all is under a Wolf hood that turns on by itself.

Wolf downdrafts have no sentry but a delay-off: press DELAY and the blower runs on about five minutes, or ten from high or medium, the second five on low.

When it is ours

A hood that runs on stone cold, ignores its controls or only stops at the breaker has a fault in the speed control, a switch or the board.

A broken knob or a wiring fault can do it too.

Checked byRafael MonteiroRoleCooking-appliance technician — ventilation and blowersIn the trade9 yearsChecked